Gage Vapour Pressure of LPG​

ASTM D1267 

IP 161 - IP 410

ISO 4256

 

Gage Vapour Pressure of Liquefied Petroleum (LP) Gases (LP-gas Method)

This test method covers the determination of the gage vapour pressures of liquefied petroleum gas products at temperatures of 37.8°C (100°F) up to and including a test temperature of 70°C (158°F).

 

Art. LT/VP-174000-A/M

Vapour Pressure Cylinder - Lower Chamber - Two Openings - ASTM D1267

 

  • Made in stainless steel

  • In one end of the chamber an opening of approximately ½" shall be provided for coupling with the vapour chamber by means of a straight-trough valve

  • Sloped inner surface

  • Provided with charging / discharging valve

  • Art. LT/VP-174000-B/M

  • Vapour Pressure Cylinder - Upper Chamber - ASTM D1267

  • Made in stainless steel

  • Lower coupling ½"

  • Complete with bleeder valve assembly and ½" coupling for pressure gauge

 

Art. LT/VP-174000-C/M

Vapour Pressure Cylinder - Lower Chamber 33 1/3% - Two Openings - ASTM D1267

 

  •  Made in stainless steel

  • In one end of the chamber an opening of approximately ½" shall be provided for coupling with the vapour chamber by means of a straight-trough valve

  • Sloped inner surface

  • Provided with charging / discharging valve

Alternative Products

 

A sentence here about related products with image links below to products you want customer to consider. 

SUBMIT

Name:

This field is required.

Thank You for your enquiry.

Your information has been sent successfully.  One of the Crea Laboratory technologies Team will be in contact with your shortly. 

 

If your enquiry is urgent, please call us on 1300 552 725

Email:

This field is required.

Phone:

This field is required.

Industry:

This field is required.

Company Name:

This field is required.

Address:

This field is required.

Post Code:

Country:

This fi.

Gage Vapour Pressure of LP

For more information on this product or to arrange a call from one of the Cea Petrochemical Team, please complete the contact form below. 

Hydrostatic test

The assembled chambers are certified by the manufacturer to withstand approx.1000 PSI (70bar) of hydrostatic pressure without permanent deformation

 

Accessories

  • LT/TB-177500/M thermostatic bath, 3 places

  • completely made in 18/8 stainless steel

  • equipped with double bottomthermostating is digitally thermoregulated PID with overtemperature alarm and probe PT100A

  • stainless steel heater working temperature up to 80°C

  • the bath is fitted with cooling coil and motor stirrersupport which allows the immersion of 3 vapour pressure cylinders or 2 density pressure hydrometer

  • atmospheric draining

  • power supply: 220 Vac 50/60 Hz

  • LAB-101-742/100: pressure gauge double scale 0-700 kPa, 0-100 Psi made in stainless steel, div. 70 kPa (10 Psi) precision 3.4 kPa (0.5 Psi)

  • LAB-101-742/250: pressure gauge double scale 0-1750 kPa, 0-250 Psi, made in stainless steel, div. 172 kPa (25 Psi) precision 7 kPa (1 Psi)

  • LAB-101-742/500: pressure gauge double scale 0-3500 kPa, 0-500 Psi, made in stainless steel, div. 344 kPa (50 Psi) precision 35 kPa (5 Psi)

  • LAB-101-743:copper capillary adaptor ∅ 6 mm × 4 mm

 

Spare Parts

LAB-101-744: gasket, pack of 10

LAB-101-745: total flow valve

 

CE marked