Gage Vapour Pressure of LPG
ASTM D1267
IP 161 - IP 410
ISO 4256
Gage Vapour Pressure of Liquefied Petroleum (LP) Gases (LP-gas Method)
This test method covers the determination of the gage vapour pressures of liquefied petroleum gas products at temperatures of 37.8°C (100°F) up to and including a test temperature of 70°C (158°F).
Art. LT/VP-174000-A/M
Vapour Pressure Cylinder - Lower Chamber - Two Openings - ASTM D1267
Made in stainless steel
In one end of the chamber an opening of approximately ½" shall be provided for coupling with the vapour chamber by means of a straight-trough valve
Sloped inner surface
Provided with charging / discharging valve
Art. LT/VP-174000-B/M
Vapour Pressure Cylinder - Upper Chamber - ASTM D1267
Made in stainless steel
Lower coupling ½"
Complete with bleeder valve assembly and ½" coupling for pressure gauge
Art. LT/VP-174000-C/M
Vapour Pressure Cylinder - Lower Chamber 33 1/3% - Two Openings - ASTM D1267
Made in stainless steel
In one end of the chamber an opening of approximately ½" shall be provided for coupling with the vapour chamber by means of a straight-trough valve
Sloped inner surface
Provided with charging / discharging valve
Alternative Products
A sentence here about related products with image links below to products you want customer to consider.
SUBMIT
Name:
This field is required.
Email:
This field is required.
Phone:
This field is required.
Industry:
This field is required.
Company Name:
This field is required.
Address:
This field is required.
Post Code:
Country:
This fi.
Gage Vapour Pressure of LP
For more information on this product or to arrange a call from one of the Cea Petrochemical Team, please complete the contact form below.
Hydrostatic test
The assembled chambers are certified by the manufacturer to withstand approx.1000 PSI (70bar) of hydrostatic pressure without permanent deformation
Accessories
LT/TB-177500/M thermostatic bath, 3 places
completely made in 18/8 stainless steel
equipped with double bottomthermostating is digitally thermoregulated PID with overtemperature alarm and probe PT100A
stainless steel heater working temperature up to 80°C
the bath is fitted with cooling coil and motor stirrersupport which allows the immersion of 3 vapour pressure cylinders or 2 density pressure hydrometer
atmospheric draining
power supply: 220 Vac 50/60 Hz
LAB-101-742/100: pressure gauge double scale 0-700 kPa, 0-100 Psi made in stainless steel, div. 70 kPa (10 Psi) precision 3.4 kPa (0.5 Psi)
LAB-101-742/250: pressure gauge double scale 0-1750 kPa, 0-250 Psi, made in stainless steel, div. 172 kPa (25 Psi) precision 7 kPa (1 Psi)
LAB-101-742/500: pressure gauge double scale 0-3500 kPa, 0-500 Psi, made in stainless steel, div. 344 kPa (50 Psi) precision 35 kPa (5 Psi)
LAB-101-743:copper capillary adaptor ∅ 6 mm × 4 mm
Spare Parts
LAB-101-744: gasket, pack of 10
LAB-101-745: total flow valve
CE marked