OilLab 620 RECC

ASTM D3828, IP 303, EN ISO, NF 3679

 

Marchio CE

 

Subject

These test methods cover procedures for the determination of the flash point by a small scale closed tester. The procedures may be used to determine the actual flash point temperature of a sample or whether a product will or will not flash at a specified temperature (flash/no flash).

 

Measuring R.E.C.C. Principle

A specimen of a sample is introduced by means of a syringe into the cup of the selected apparatus that is set and maintained at the specific temperature/expected flash point. After a specified time a test flame is applied and the observation made whether or not a flash occurred.

 

Measuring R.E.C.C. Devices

  • Testing unit equipped with two ignition systems

  • Electrical system or flame exposure device

  • Flash point detected by a ionization system

 

Measuring Temperature Probe

  • Platinum resistance PT100 class A

 

Measuring Parameters

  • Temperatures: in °C

  • Measuring range: –50°C … +350°C

  • Resolution: 0.06 °C

  • Accuracy: ± 0.1 °C

  • Repeatability / Reproducibility: as per standards methods or better

 

LabLink operating Software

User friendly

  • interface

  • All analytical parameters recorded

  • Customizable analysis parameters and methods

  • Customizable results report

  • Printable graphs and results

  • Self-identification of the typology of the analysers connected

 

The software includes:

 

Analysis Menu

Unknow

  • Standard method as per ASTM / IP / ISO / EN / DIN… norms of reference

  • sampleAudible alarm and displayed messages at the end of the analysis and in case of errors and/or malfunctions

 

Diagnostic Menu

Direct access to all analog, digital, inputs and outputs

Selectable value displaying: °C / Volt

 

Calibration Menu

  • Automatic calibration of each temperature probe

  • Last calibration date referred to each single probe displayed and relative data printable

  • Display of calibration diagram

  • Insertion of offset values

  • Standard and advanced calibration modes

 

Data Utilities

  • Fields for introduction of operator and product name

  • Archive viewer for files recall

  • All analysis stored in Excel® compatible format

  • Storage capacity for more than 60’000 analysis

  • LIMS compatible

 

Integrated Touch Screen Panel PC

  • TFT/LCD 8"

  • Resolution 1024 × 768, 16.2 M colours

  • USB port for connection to an external printer and/or external PC

  • Storage capacity for more than 60'000 analysis

 

Test Cup

  • The cup is made of aluminium and equipped with high temperature resistant o-ring

 

Heating

  • Electrical heating cartridges

  • Equipped with over temperature cut-out

 

Cooling System

  • Air fan

 

Warning light and acoustic signal

When the test temperature is reached, the light blink and an acoustic signal is emitted to inform the operator that the sample must be injected.If the injection of the sample is not performed and confirmed the signal will be repeated after 30 seconds.

 

Shutter

  • Automatic mechanism opening the shutter conform to the methods

 

Electrical Supply

  • 220V ± 15% / 50 to 60 Hz

  • 115V ± 15% / 60 Hz

 

Cord Cable

  • 3 conductors flexible cable with schuko plug

 

Ambient Temperature

  • Max 35°C

  • H.R. 80%

 

Dimensions

  • width 31 cm

  • depth 47 cm

  • height 52 cm

 

Weight

  • 27 kg

 

Spare Parts

  • LAB-620/05-13: heating cartridges

  • LAB-620/06-21: gas valve

  • LAB-620/07-01: electrical ignitor

  • LAB-620/07-03: micro switch

  • LAB-620/07-05: gas ignitor

  • LAB-620/08-12: PT100 sensor

  • LAB-620/08-13: detection / Ionisation cable

  • LAB-620/09-04: gas reducer

  • LAB-620/10-04: PCB fuses, box of 10

  • LAB-620/10-05: main electronic board

  • LAB-620/11-01: silicon tubing, 1 meter

  • LAB-620/12-01: voltage transformer for ignitorLAB-620/13-01: high temperature resistant o-ring for cup

 

Calibration Tools


 

  • OilLab 80: calibration decade box – PT100 simulator

  • OilLab 81: set of connectors and cables for cold range

Alternative Products

 

A sentence here about related products with image links below to products you want customer to consider. 

SUBMIT

Name:

This field is required.

Thank You for your enquiry.

Your information has been sent successfully.  One of the Crea Laboratory technologies Team will be in contact with your shortly. 

 

If your enquiry is urgent, please call us on 1300 552 725

Email:

This field is required.

Phone:

This field is required.

Industry:

This field is required.

Company Name:

This field is required.

Address:

This field is required.

Post Code:

Country:

This fi.

OilLab 620 RECC

For more information on this product or to arrange a call from one of the Cea Petrochemical Team, please complete the contact form below.