OilLab 650 - Abel Flash Point​

Standards

EN 924, EN 13736, IP 170, IP 491, IP 492, ISO 1516, ISO 3679, ISO 13736

 

CE marked

 

Subject

Flash point on petroleum products having a flash point between -18°C and 71°C (kerosene and solvents). Suitable for flash point detection on different substances and waste materials, solvents…

 

Measuring Abel Principle

The sample is warmed up according to the methods. When the sample reaches the selected test temperature, the shutter is opened and the ignition system introduces itself automatically. If the flash point is reached, the detection is done by an ionisation detector. If not, the shutter closes again and the sample continues to warm up until the next test temperature.

 

Measuring Abel Devices

  • Measurement of the Flash Point detected by an ionisation detector

  • Testing unit equipped with two ignition systems

  • Electrical system or flame exposure device

 

Measuring Temperature Probe

  • Platinum resistance PT100 class A

 

Measuring Parameters

  • Temperatures: in °C

  • Measuring range: -50°C … +100°C

  • Resolution: 0.06 °C

  • Accuracy: ± 0.1 °C

  • Repeatability / Reproducibility: as per standards methods or better

 

Software Features

  • User friendly interface

  • All analytical parameters recorded

  • Customizable analysis parameters and methods

  • Customizable results report

  • Printable graphs and results

  • Self-identification of the typology of the analysers connected

 

The software includes:

 

Analysis Menu

Standard method as per ASTM / IP / ISO / EN / DIN… norms of reference

Unknow sample

Audible alarm and displayed messages at the end of the analysis and in case of errors and/or malfunctions

 

Diagnostic Menu

  • Direct access to all analog, digital, inputs and outputs

  • Selectable value displaying: °C / Volt

 

Calibration Menu

  • Automatic calibration of each temperature probe

  • Last calibration date referred to each single probe displayed and relative data printable

  • Display of calibration diagram

  • Insertion of offset values

  • Standard and advanced calibration modes

 

Data Utilities

  • Fields for introduction of operator and product name

  • Archive viewer for files recall

  • All analysis stored in Excel® compatible format

  • Storage capacity for more than 60’000 analysis

  • LIMS compatible

 

Integrated Touch Screen Panel PC

TFT/LCD 8"

Resolution 1024 × 768, 16.2 M colours

USB port for connection to an external printer and/or external PC

Storage capacity for more than 60'000 analysis

 

Test Cup

The cup is made of brass provided with high temperature resistant handle

Sample level mark

 

Heating

Electrical heater

Equipped with over temperature cut-out

 

Cooling System

Liquid refrigerant controlled by internal solenoid valve

 

Stirrer

An electric motor drives a flexible transmission coil allowing the stirring of the product

 

Shutter

Automatic mechanism opening the shutter conform to the methods

 

Accessories

  • External Cryostat:
  • LT-900/35/3, single stage, up to -40°C
  • LT-900/80/3, double stage, up to -80°C

 

Electrical Supply

  • 220V ± 15% / 50 to 60 Hz

  • 115V ± 15% / 60 Hz

 

Cord Cable

  • 3 conductors flexible cable with schuko plug

 

Ambient Temperature

  • Max 35°C

  • H.R. 80%

 

Dimensions

  • width 48 cm

  • depth 37 cm

  • height 61 cm

 

Weight

  • 32 kg

 

Spare Parts

  • LAB-650/05-13: heater

  • LAB-650/05-16: PT100 bath

  • LAB-650/06-11: cooling valve

  • LAB-650/06-12: insulated tube for connection to external cryostat

  • LAB-650/06-21: gas valve

  • LAB-650/07-01: electrical ignitor

  • LAB-650/07-03: micro switch

  • LAB-650/07-04: handle

  • LAB-650/07-05: gas ignitor

  • LAB-650/08-12: PT100 product

  • LAB-650/08-13: detection / ionisation cable

  • LAB-650/09-04: gas reducer

  • LAB-650/09-05: calibrated brass crucible

  • LAB-650/09-06: calibrated brass crucible complete with movement

  • LAB-650/09-07: cover cup movement only

  • LAB-650/10-04: PCB fuses, box of 10

  • LAB-650/10-05: main electronic board

  • LAB-650/11-01: silicon tubing, 1 meter

  • LAB-650/11-02: stirrer / flexible

  • LAB-650/12-01: voltage transformer for ignitor

  • LAB-650/20-01: support PT100 Teflon

 

Calibration Tools

  • OilLab 80: calibration decade box – PT100 simulator

  • OilLab 81: set of connectors and cables for cold range

Downloads

 