Oxidation Stability of Gasoline and Aviation Fuels
ASTM D525 - ASTM D873
DIN 51780 - DIN 51799
IP 40 - IP 138
ISO 7536
ASTM D525 - IP 40 - DIN 51780 - ISO 7536 - Oxidation Stability of Gasoline (Induction Period Method)
This test method covers the determination of the stability of gasoline in finished form only, under accelerated oxidation conditions.
ASTM D873 - IP 138 - DIN 51799 - Oxidation Stability of Aviation Fuels (Potential Residue Method)
This test method covers the determination of the tendency of aviation reciprocating, turbine, and jet engine fuels to form gum and deposits under accelerated ageing conditions.
Art. LT/OS-201000-2/M
Oxidation Stability Bath (2 places) - ASTM D525
- Completely made in stainless steel
- About 30 litres capacity
- Heated by electric stainless steel heater controlled by a thermoregulator
- Cover serves as condenser with connections for water circulation
- Temperature range: ambient to 100°
Art. LT/OS-201000-4/M
Oxidation Stability Bath (4 places)
- Completely made in stainless steel
- About 40 litres capacity
- Heated by electric stainless steel heater controlled by a thermoregulator
- Cover serves as condenser with connections for water circulation
- Temperature range: ambient to 100°
Power Supply
220Vac 50/60 Hz
Dimensions
cm 60 × 60 × 100
Weight
kg 65
Alternative Products
A sentence here about related products with image links below to products you want customer to consider.
SUBMIT
Name:
This field is required.
Email:
This field is required.
Phone:
This field is required.
Industry:
This field is required.
Company Name:
This field is required.
Address:
This field is required.
Post Code:
Country:
This fi.
Oxidation Stability of Gasoline and Aviation Fuels
For more information on this product or to arrange a call from one of the Cea Petrochemical Team, please complete the contact form below.
Accessories for ASTM D525 - D873
- LT/OPV-200000: oxidation pressure vessel made in stainless steel, complete with o-ring, stem needle valve, fast connection, 30 bar pressure certificate
- LAB-102-013: junction for O2
- LAB-102-014: pressure reducer
- LAB-102-001-DPS-RF-30: digital manometer with record functions
- autonomous battery powered instrument with digital display designed to record pressure and temperature over long periods
- application: 0 … 30 bar
- resolution: 10 mbar
- supply 3,6 V lithium battery, type SL-760
- all standard instruments are calibrated in bar; the pressure can be indicated in the following units: bar, mbar/hPa, kPa, MPa, PSI, kp/cm², (m)H2O
- supplied with connection cable for data transfer
- LAB-102-001-K104/A: converter cable with Fischer plug
- Fischer plug for connection of RS485A/B (without supply)
- cable length: 1,8 m
- galvanic isolation of communication
- LED for indication of communication activity
- driver software also included in delivery
- LAB-102-001/2: recorder pressure gauge, Bourdon spring, range 0-50 bar, equipped with 2 pens (red+blue), and plexiglass graduated plate (double scale)
- LAB-102-001/3: recorder pressure gauge, Bourdon spring, range 0-50 bar, equipped with 3 pens (red+blue+green), and plexiglass graduated plate (triple scale)
- LAB-102-012: pressure trasmitting capillary (for connection to the vessel)
- LAB-102-001/P: spare pen, colour must be specified on PO
- LAB-102-001/S: pack of 500 diagrams sheet
Spare Parts
LAB-110-012: heater
LAB-140-002: PT 100 probe
LAB-160-014: digital thermoregulator
LAB-150-015: static relay
LAB-150-022: motor for stirrer
CE marked