Tag Closed Flash Point​

ASTM D56, ASTM D3934, ASTM D3941, BS 6664-3 (obs.), BS 6664-4 (obs.), DIN 55680 (obs.), EN 456 (obs.), EN 924, FTM 791-1101, IP 304-1 (obs.), IP 304-2 (obs.), IP 491, IP 492, ISO 1516, ISO 1523, ISO 3679, ISO 3680, JIS K 2265, NF T60-616 (obs.), NF T60-617 (obs.)

 

Flash Point by Tag Closed TesterThis test method covers the determination of the flash point of liquids with a viscosity below 5.5 mm²/s (cSt) at 40°C (104°F), or below 9.5 mm²/s (cSt) at 25°C (77°F), and a flash point below 93°C (200°F).

 

Flash / No Flash Test - Equilibrium Method by a Closed Cup ApparatusThis test method covers the determination of whether a liquid complies with the closed-cup flash. This test method is limited to a temperature range between 0 and 110°C (32 and 230°F).

 

Flash Point by Equilibrium Method with a Closed Cup ApparatusThis test method covers the determination of the flash point of liquids in which the specimen and the air/vapour mixture above it are approximately in temperature equilibrium. This test method is limited to a temperature range between 0 and 110°C (32 and 230°F).

Alternative Products

 

A sentence here about related products with image links below to products you want customer to consider. 

SUBMIT

Name:

This field is required.

Thank You for your enquiry.

Your information has been sent successfully.  One of the Crea Laboratory technologies Team will be in contact with your shortly. 

 

If your enquiry is urgent, please call us on 1300 552 725

Email:

This field is required.

Phone:

This field is required.

Industry:

This field is required.

Company Name:

This field is required.

Address:

This field is required.

Post Code:

​

Country:

This fi.

Tag Closed Flash Point

For more information on this product or to arrange a call from one of the Cea Petrochemical Team, please complete the contact form below. 

Art. LT/TC-93000/M

Electric Tag Closed - ASTM D56 D3934 D3941

 

  • Electrically heated by electronic regulator

  • Mounted on a case painted with anti-acid epoxy products

  • Test copper cup equipped with glide-device and gas-ignition

  • Water bath and support-jacket made in brass

  • Internal cooling coil

 

Power Supply

220Vac 50/60 Hz

 

Dimensions

cm 40 × 40 × 50

 

Weight

8 kg

 

Accessories

LT/CB-40800-M/30: cryostatic bath -30°C

LAB-100-749: gas reducer 30 mbar

LAB-100-750: rubber tube-joint and tube 5 m

T-AS57C: thermometer ASTM 57C

T-AS57F: thermometer ASTM 57F

T-AS9C: thermometer ASTM 9C - IP 15C

T-AS9F: thermometer ASTM 9F - IP 15F

 

Spare Parts

LAB-100-751: silicone tubing 5 m

LAB-100-932: copper cup, pack of 2

LAB-100-933: complete movement

LAB-110-022: heater

LAB-150-110: electronic regulator

 

CE marked